Skip to content
Covering London and the home counties

Specialist metal roofing support
from first sketch to handover

Zinc, copper and aluminium roofs and façades for commercial and large residential schemes. We can design the package, insure that design and install it — one team from feasibility to handover.

Design stage

How we support you at design stage

Bring us in early. Small changes at Stage 2 or 3 cost far less than redesign later. [CLIENT TO CONFIRM]

01

Early design input

We review your drawings and advise on seam layout, falls, junctions and details that work in metal.
02

System and manufacturer

Standing seam, flat lock, shingles or cassettes. We help you choose the system and maker for the look, budget and warranty you need.
03

Typical build-ups

Warm or cold, roof or wall. Build-ups come with U-values and condensation risk checks from the manufacturer.
04

Budget costs

Rates per m² for feasibility and client approval, firmed up as the design develops.
05

Site visits

For refurbishments and tricky interfaces we visit before we price, so there are no surprises.
06

Fixed price and programme

A fixed price with clear inclusions and exclusions, and a programme that fits yours.
How a job runs

Where we fit in,
stage by stage

Mapped to the RIBA Plan of Work. Join at any stage. [CLIENT TO CONFIRM]

  1. RIBA 1–2

    Early advice

    System options, first details and feasibility costs.

  2. RIBA 3

    Developed design

    Build-ups, U-values, condensation and wind checks. Budget firmed up.

  3. RIBA 4

    Technical design

    Our package drawings and calculations, for your approval.

  4. Tender

    Fixed price

    Itemised price, programme, RAMS and insurance certificates.

  5. RIBA 5

    On site

    A sample panel signed off first, a named supervisor, weekly photo reports.

  6. RIBA 6

    Handover

    O&M manual, as-built drawings and warranties for the H&S file.

Typical build-ups

Warm roof or cold roof?

Two common build-ups under a standing seam roof, drawn outside to inside.

Warm roof

Insulation above the structure. Suits low pitches and flat roofs.

  1. Standing seam zincDouble-lock seams, fixed with clips
  2. Structured underlayLets moisture drain from under the metal
  3. Plywood deckFixing base for the clips
  4. Rigid insulationThickness set by the U-value
  5. Vapour control layerSealed at every joint
  6. Structural deck
  7. StructureJoists, purlins or concrete

Cold roof

Insulation between the rafters, with a ventilated gap above.

  1. Standing seam zincDouble-lock seams, fixed with clips
  2. Structured underlay
  3. Plywood deck
  4. Ventilated air gapOpen at eaves and ridge
  5. Breather membrane
  6. Insulation between raftersMineral wool
  7. Vapour control layerOn the warm side
  8. Rafters and ceiling

Typical only. Every build-up is confirmed with the manufacturer for U-value, condensation risk (BS 5250) and wind load. [CLIENT TO CONFIRM]

Design responsibility

Who signs off what

Agreed at tender and written into the subcontract, so nothing falls between us. [CLIENT TO CONFIRM]

Your design teamZinc Roofing Company
Overall design and appearanceLead and decideAdvise on what works in metal
System and finishSpecifyOptions, samples and manufacturer data
Build-ups and U-valuesApprovePrepare, with manufacturer calculations
Condensation riskApprovePrepare, with manufacturer analysis
Wind uplift and fixingsEngineer checks the structureDesign fixings to BS EN 1991-1-4
Metalwork detailsComment and approveDraw and design, covered by our PI insurance
Interfaces with other tradesCoordinateFlag clashes and propose details
CDM designer dutiesFor your designFor our package design

A typical split where we design the metal roofing package. On a build-only package, we install to your details.

The paperwork

What a main contractor or QS will ask for

Short answers here. Full documents come with our tender, or on request.

01

Insurance

Employer's and public liability, and professional indemnity for our design work. Certificates with every tender. [CLIENT TO CONFIRM] cover levels
02

Design responsibility

We can take on design of the metal roofing and cladding package, as set out in the subcontract, covered by our PI insurance.
03

Health and safety

Method statements and risk assessments (RAMS) for every job. We meet our CDM 2015 duties as contractor and as designer of our package. [CLIENT TO CONFIRM] SSIP scheme
04

Fire and Building Regulations

Zinc, copper and aluminium are non-combustible. We give you the fire classification of every layer, for Approved Document B. [CLIENT TO CONFIRM] per system
05

Warranties

The manufacturer's material warranty plus our own workmanship guarantee. Collateral warranties on request. [CLIENT TO CONFIRM] terms
06

Contracts and payment

We work on JCT and NEC subcontracts, with clear payment applications valued against the programme. [CLIENT TO CONFIRM] bonds and retentions
07

Prequalification

Accounts, policies, references and case studies for your PQQ or PAS 91 questionnaire. [CLIENT TO CONFIRM] schemes held
08

Quality on site

A sample panel signed off before we start, a named supervisor and weekly photo reports. [CLIENT TO CONFIRM] CSCS and manufacturer training
09

Handover

O&M manual, as-built drawings, product data and warranties, ready for the health and safety file and the golden thread.
Systems

Systems and manufacturers

We install the leading metal roofing and cladding systems, approved by the maker where they offer it.

What clients say

Trusted on commercial work

01 / 03
I would like to take this opportunity to say how pleased we are with the way the job was done, and the team that carried out the work were helpful and professional.
DaveClient
What a refreshing change to find a company that not only gave a speedy quotation but, with first class office back up, kept to programme, did a first class job and completed on time with no extras. The bonus was that they were a pleasure to have around.
Gary JenkinsMain contractor
We are very happy with the work that Zinc Roofing have done for us. The work was high quality, on time and on budget. We will definitely be working with these guys again.
Chris ChildClient

Questions architects ask

What do you need to give us a price?

Drawings as PDF or DWG, the specification if there is one, and your programme. For a budget figure, a sketch and rough areas are enough.

Who is responsible for the design of the details?

It is agreed at tender and written into the subcontract. We can design the metal roofing package and its details, covered by our professional indemnity insurance. You approve our drawings; your structural engineer checks the structure.

Do you carry professional indemnity insurance?

Yes. Our design work is covered by professional indemnity insurance, and certificates come with our tender. [CLIENT TO CONFIRM] level of cover

How do metal roofs meet fire safety rules?

Zinc, copper and aluminium are non-combustible. Roof coverings are classified under BS EN 13501-5, and taller buildings need non-combustible wall build-ups under Approved Document B. We give you each layer's fire classification. [CLIENT TO CONFIRM] per system

What are your lead times?

Tell us your start date at tender and we will confirm a programme. Pre-weathered and coloured finishes can take longer to arrive, so we order them early. [CLIENT TO CONFIRM] typical weeks

What warranty do we get?

Two parts: the manufacturer's warranty on the material and our own workmanship guarantee. Collateral warranties to funders or tenants can be arranged. [CLIENT TO CONFIRM] terms

Which areas do you cover?

London, Kent, Essex, Sussex and Surrey, from our base in Dartford. Ask us about larger projects further afield.

Is there a minimum project size?

No fixed minimum. We work on everything from a single dormer to large commercial roofs. [CLIENT TO CONFIRM]

Ready when you are

Send us your
drawings

We'll come back with advice, a budget figure or a fixed price, whatever stage you're at.

  • PDF or DWG drawings welcome
  • Design, insurance and installation in one package