Specialist metal roofing support
from first sketch to handover
Zinc, copper and aluminium roofs and façades for commercial and large residential schemes. We can design the package, insure that design and install it — one team from feasibility to handover.
How we support you at design stage
Bring us in early. Small changes at Stage 2 or 3 cost far less than redesign later. [CLIENT TO CONFIRM]
Early design input
System and manufacturer
Typical build-ups
Budget costs
Site visits
Fixed price and programme
Where we fit in,
stage by stage
Mapped to the RIBA Plan of Work. Join at any stage. [CLIENT TO CONFIRM]
-
RIBA 1–2
Early advice
System options, first details and feasibility costs.
-
RIBA 3
Developed design
Build-ups, U-values, condensation and wind checks. Budget firmed up.
-
RIBA 4
Technical design
Our package drawings and calculations, for your approval.
-
Tender
Fixed price
Itemised price, programme, RAMS and insurance certificates.
-
RIBA 5
On site
A sample panel signed off first, a named supervisor, weekly photo reports.
-
RIBA 6
Handover
O&M manual, as-built drawings and warranties for the H&S file.
Warm roof or cold roof?
Two common build-ups under a standing seam roof, drawn outside to inside.
Warm roof
Insulation above the structure. Suits low pitches and flat roofs.
- Structured underlayLets moisture drain from under the metal
- Plywood deckFixing base for the clips
- Rigid insulationThickness set by the U-value
- Vapour control layerSealed at every joint
- Structural deck
- StructureJoists, purlins or concrete
Cold roof
Insulation between the rafters, with a ventilated gap above.
- Structured underlay
- Plywood deck
- Ventilated air gapOpen at eaves and ridge
- Breather membrane
- Insulation between raftersMineral wool
- Vapour control layerOn the warm side
- Rafters and ceiling
Typical only. Every build-up is confirmed with the manufacturer for U-value, condensation risk (BS 5250) and wind load. [CLIENT TO CONFIRM]
Who signs off what
Agreed at tender and written into the subcontract, so nothing falls between us. [CLIENT TO CONFIRM]
| Your design team | Zinc Roofing Company | |
|---|---|---|
| Overall design and appearance | Lead and decide | Advise on what works in metal |
| System and finish | Specify | Options, samples and manufacturer data |
| Build-ups and U-values | Approve | Prepare, with manufacturer calculations |
| Condensation risk | Approve | Prepare, with manufacturer analysis |
| Wind uplift and fixings | Engineer checks the structure | Design fixings to BS EN 1991-1-4 |
| Metalwork details | Comment and approve | Draw and design, covered by our PI insurance |
| Interfaces with other trades | Coordinate | Flag clashes and propose details |
| CDM designer duties | For your design | For our package design |
A typical split where we design the metal roofing package. On a build-only package, we install to your details.
What a main contractor or QS will ask for
Short answers here. Full documents come with our tender, or on request.
Insurance
Design responsibility
Health and safety
Fire and Building Regulations
Warranties
Contracts and payment
Prequalification
Quality on site
Handover
Systems and manufacturers
We install the leading metal roofing and cladding systems, approved by the maker where they offer it.
Projects with architects
Recent schemes delivered with architects' design teams.

- Architect
- De Rosee Sa Architects
- Material
- VM Zinc Pigmento Red
- Area
- 90 m²

- Architect
- Kirkland Fraser Moor
- Material
- KME TECU Classic copper

- Architect
- Sheppard Robson
- Material
- elZinc Rainbow Green
- Area
- 900 m²

- Architect
- AMA Architects
- Material
- GreenCoat PLX Nordic Night Black
I would like to take this opportunity to say how pleased we are with the way the job was done, and the team that carried out the work were helpful and professional.
What a refreshing change to find a company that not only gave a speedy quotation but, with first class office back up, kept to programme, did a first class job and completed on time with no extras. The bonus was that they were a pleasure to have around.
We are very happy with the work that Zinc Roofing have done for us. The work was high quality, on time and on budget. We will definitely be working with these guys again.
Questions architects ask
What do you need to give us a price?
Drawings as PDF or DWG, the specification if there is one, and your programme. For a budget figure, a sketch and rough areas are enough.
Who is responsible for the design of the details?
It is agreed at tender and written into the subcontract. We can design the metal roofing package and its details, covered by our professional indemnity insurance. You approve our drawings; your structural engineer checks the structure.
Do you carry professional indemnity insurance?
Yes. Our design work is covered by professional indemnity insurance, and certificates come with our tender. [CLIENT TO CONFIRM] level of cover
How do metal roofs meet fire safety rules?
Zinc, copper and aluminium are non-combustible. Roof coverings are classified under BS EN 13501-5, and taller buildings need non-combustible wall build-ups under Approved Document B. We give you each layer's fire classification. [CLIENT TO CONFIRM] per system
What are your lead times?
Tell us your start date at tender and we will confirm a programme. Pre-weathered and coloured finishes can take longer to arrive, so we order them early. [CLIENT TO CONFIRM] typical weeks
What warranty do we get?
Two parts: the manufacturer's warranty on the material and our own workmanship guarantee. Collateral warranties to funders or tenants can be arranged. [CLIENT TO CONFIRM] terms
Which areas do you cover?
London, Kent, Essex, Sussex and Surrey, from our base in Dartford. Ask us about larger projects further afield.
Is there a minimum project size?
No fixed minimum. We work on everything from a single dormer to large commercial roofs. [CLIENT TO CONFIRM]
Send us your
drawings
We'll come back with advice, a budget figure or a fixed price, whatever stage you're at.
- PDF or DWG drawings welcome
- Design, insurance and installation in one package